Skip to content

Product Summary

The Norseman™ XGB Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the most challenging conditions. Norseman™ XGB unit heaters are available in two sizes: small cabinet units with ratings of up to 10 kW and large cabinet units with ratings of up to 35 kW. The Norseman™ line provides innovative forced air or natural convection solutions to your hazardous area heating requirements, from panel heaters to unit heaters. The Norseman™ XGB is designed specifically for heating industrial spaces where potentially explosive substances are or may be present. Typical hazardous location environments include:
  • Water and sewage treatment plants
  • Oil refineries
  • Compressor stations
  • Pulp and paper mills
  • Paint storage booths
  • Cement plants
  • Mines
  • Marine and offshore Certification Certified by CSA to Canadian and US standards, with standard models approved for the following:
  • Class I, Division 1 2, Groups C D
  • Class II, Division 1, Groups E, F G
  • Class II, Division 2, Groups F G
  • What's Included

      (1) Norseman™ XGB Series Explosion-Proof Convection Heater c/w T'stat, 35 kW, 480V, 3Ø, 119,420 BTU/Hr

    Features + Benefits

    • XGB Explosion-Proof Forced Air Heaters Designed for Hazardous Locations
    • Applications The Norseman™ XGB is designed specifically for heating industrial spaces where potentially explosive substances are or may be present. Typical hazardous location environments include:
    • Water and sewage treatment plants
    • Oil refineries
    • Compressor stations
    • Pulp and paper mills
    • Paint storage booths
    • Cement plants
    • Mines
    • Marine and offshore
    • Certification Certified by CSA to Canadian and US standards, with standard models approved for the following:
    • Class I, Division 1 & 2, Groups C & D
    • Class II, Division 1, Groups E, F & G
    • Class II, Division 2, Groups F & G NOTE: Group B and 50 Hz constructions available on large cabinet construction only on special request. Class II and some atmospheric groups are not available in every kW rating.
    • Flow Adjustment In structures with high ceilings, other units may not have the range of motion needed to direct air flow to the floor. The XGB allows the unit to be tilted at a 30° angle below the horizontal. For lateral airflow, the entire louvre assembly can be rotated 90°.
    • No Conduit Seal Required A factory installed conduit seal provides the necessary isolation between the supply and control housings. In Division 2, Zone 2 applications, a field installed conduit seal may not be required.
    • Simplified Wiring To facilitate installation, the Norseman™ explosion-proof unit heaters feature Thermon Heating Systems’ patented x-Max® housing with slide out terminal block trolley for connection of the electrical supply.
    • 1/2 HP explosion-proof motor
    • Inlet wire guard
    • Extra heavy wall tubular steel finned heating elements with nickel plated finish
    • Patented x-Max® explosion-proof terminal housing
    • 120V control circuit includes: – Derated magnetic contactor – Dual automatic reset high limits – Transformer
    • Heavy duty 16-gauge stainless steel casing
    • Outlet louvre assembly
    • Swivel bracket
    • Factory installed conduit seal
    • Supply connection housing
    • Terminal block for supply wiring and thermostat connection
    • Mounting Accessories Ceiling mount kit; Wall mount kit; Post mount kit; Floor stand kit􀀁
    • Thermostats Thermon Heating Systems offers a wide variety of explosion-proof thermostats to suit most every need􀀁 Norseman™ unit heaters are available with optional built-in, externally adjustable, bulb-type thermostats􀀁 Thermostats for remote mounting can be provided upon request􀀁
    • Motors Fractional horsepower, 1725 RPM explosion-proof motor with double shielded ball bearings and built-in thermal overload􀀁 Small cabinet units use 1/12 HP motor approved for Class I, Group D; Class II, Groups F and G􀀁 Large cabinet units use 1/2 HP motor approved for Class I, Groups C and D; Class II, Groups E, F and G, as standard􀀁

    Key Specs

    AttributeSpecification

    item#

    7388597

    Brand

    Norseman

    Manufacturer's Warranty

    1 year limited warranty

    Ship Weight

    230.0 LB

    Heat Type

    Convection

    Heat Output

    119,420 Btu/hour

    Phase

    Three-phase

    Indoor Outdoor Use

    Indoor

    Volts

    480
    AttributeSpecification

    Watts

    35,000

    Amps

    43

    Hardwired

    Yes

    Thermostat Included

    Yes

    Mounting Hardware Included

    No

    Housing Material

    Stainless Steel

    Hazardous Location Rating

    CSA C/US Certified for hazardous locations. Small cabinet units approved for Class I, Div 1 & 2, Group D; Class II, Div. 1 & 2, Groups E, F and G. Large cabinet units approved for Class I, Div. 1 & 2, Groups C & D; Class II, Div. 1 &

    Product Weight

    230.0000 lb

    Dimensions L x W x H (in.)

    36.0 x 27.0 x 40.0 in

    Warranty

    Manufacturer's Warranty

    1 year limited warranty