you have to remove it to clean your stove pipe but this is simple ...two screws. I do it every year and i'm a 50+ women.. by no means a builder or handi-man
Free Gift Card Details
- The promotion will be automatically applied on the Shopping Cart page.
- To qualify for this offer, your order subtotal must equal $100 or more. Excludes gift cards, free item offers, warranties, Advantage memberships, tax and shipping.
- Free gift cards will be issued in the form of e-gift cards only, not physical gift cards.
- E-gift cards will be sent to the email address used in your billing address when your order ships or is picked up.
- Free e-gift cards expire 10/01/26.
- Promo code not valid on prior purchases or on Honda and STIHL products and cannot be combined with other promotional offers.
- Valid online and in participating retail stores.
- Limited-time offer. Subject to change without notice.
Magic Heat™ Reclaimer for Wood, Oil or Coal Stove — 8 in., Model# MH-8-R

This is a carousel with one large zoomable image and a track of thumbnails on the left. Select any of the thumbnail buttons to change the zoomable image on the right. If a thumbnail is a video or 360 degree image thumbnail, or the last thumbnail in the list, the button will open the product media modal.

Click or Tap image to Zoom
This item is no longer available.
- Can not be used horizontally
- Blower fan has 6ft, 3 prong plug
- Allow 18in. clearance between stove and heat reclaimer
- Crimp on the bottom
See full description
Description
Key Specs
Reviews
Q & A
Warranty
Compare
Product Summary
Downloads
Features + Benefits
- Can not be used horizontally
- Blower fan has 6ft, 3 prong plug
- Allow 18in. clearance between stove and heat reclaimer
- Crimp on the bottom
Key Specs
| Attribute | Specification |
|---|---|
item# | 17279 |
Brand | Magic Heat |
Manufacturer's Warranty | 12 months parts / 12 months labor |
Ship Weight | 26.0 LB |
Included (qty.) | 1 |
| Attribute | Specification |
|---|---|
Compatible With | Wood, Oil or Coal Stoves |
Height | 18.25 in |
CFM | 225 cfm |
Volts | 115 |
Dimensions L x W x H (in.) | 10.625 W x 14.25 D x 18.25 H in |
Reviews
Questions & Answers
Questions
-
· 16 years ago
Will I be able to clean stovepipe with this installed?
Does this device interfere with the inside diameter of the stove pipe? In other words, will I still be able to use my stove pipe brush (same diameter as inside stove pipe) all the way from the top down to the stove? Or do the heat reclaimers reduce the inside diameter of my stove pipe to the parallel spaces between heat collectors, without a means of cleaning the soot that builds up there?
-
nature· 16 years ago
Helpful?
-
Frederic· 16 years ago
The unit has a built in cleaner for scraping the tubes. You can actually clean the stove pipe from above without removing the unit but you must work carefully so as not to damage the tubes.
Helpful?
-
ProductExpert12· 16 years ago
The heat reclaimer will need to be removed when cleaning the stove pipe due to the exchanger tubes in the reclaimer.
Helpful?
-
-
· 13 years ago
does this effect drafting
i will be using this in a modern mid efficiency wood stove, will this in any way effect the drafting pressures or change the way the chimney functions causing smoke to enter the room
-
Anonymous· 13 years ago
No
Helpful?
-
ProductExpert25· 13 years ago
The Magic Heat Reclaimer, when properly installed, will not affect drafting of a properly installed stove. Always check with local codes and ordinances to be sure you are in compliance.
Helpful?
-
-
· 13 years ago
6" flue vs 8" flue
I measured my pipe diameter on the boiler and it measured 7", would I use a 6" or 8" Magic Heat Reclaimer? or am I out of luck and can not use either unless having to customize an adapter fitting.
-
Anonymous· 13 years ago
You will have to use an 8" with a 8"x7" reducer on the top and bottom of the heat reclaimer. If you can't find 8"x7" reducers they could be custom made in a shop. Using a 6" heat reclaimer would reduce the normal draft.
Helpful?
-
ProductExpert40· 13 years ago
The Magic Heat Reclaimer for wood, oil, or coal stove comes in two flue sizes only. The six inch model and the 8 inch model. A seven inch flue would not fit with either unit.
Helpful?
-
-
· 13 years ago
does the damper on a wood stove have to be below or above the heat exchanger
-
Anonymous· 13 years ago
The damper should be below the heat exchainger.
Helpful?
-
ProductExpert26· 13 years ago
The damper should be installed below the Magic Heat reclaimer.
Helpful?
-
-
Anonymous· 14 years ago
I have a free standing coal stove (manually fed)..I want to direct some heat into the adjacent room..is this product what I'm looking for to do this?
The coal stove is placed between two rooms, but the room with the vaulted ceiling (obviously) doesn't feel as warm as the other room..my only other idea is to put a floor fan near the stove to help move more warm air into the room. Thanks for any help!
-
Anonymous· 13 years ago
Heat rises, so most of the heat may be rising to the ceiling, in the room with the vaulted ceiling, so it feels colder at the lower level. Put a ceiling fan in the vaulted ceiling room to circulate the heat to a lower level.
Helpful?
-
ProductExpert40· 14 years ago
The Magic Heat Reclaimer for wood, oil, or coal stoves is designed to recapture heat which is otherwise lost through the flue pipe. The unit fits on the flue pipe and blows warm air into the room. This might indeed help heat the second room with the vaulted ceiling but just how much it will help can only be verified through actually installing the unit and testing. Your idea of using a floor fan near the stove to help move more warm air into the second room could help also.
Helpful?
-
-
· 16 years ago
To install this reclaimer, is the flue simply cut, and a section taken out and replaced with the unit?
Would also like to know if single wall, or double wall flue pipe makes a difference?
-
ProductExpert10· 16 years ago
It is not recommended that you simply cut the pipe and remove the section. The reclaimer needs at least 18" of clearance from the stove and added to the existing or new pipe.
Helpful?
-
nature· 16 years ago
i have a dbl wall flue pipe cause it runs 20' next to stair well and keeping the heat off the wood and where the kids could touch it was a concern.
Helpful?
-
-
· 16 years ago
If the stove is on the main floor can the Magic Heat be installed on the second floor
-
nature· 16 years ago
heat is what makes this product work so i guess the question would be how much heat are you loosing up your stove pipe. I would guess yes it may take a little while to start cause it has to reach temp but i say once it reaches temp you should be ok. it does not effect the flow up your pipe. Just reclaims the lost heat.
Helpful?
-
ProductExpert7· 16 years ago
For proper function, you want to install the reclaimer 18" from the stove.
Helpful?
-
-
Anonymous· 13 years ago
Can I use a single wall adapter to Double wall pipe
Can I use a single wall adapter pipe to go from my double wall 6" pipe to the 8" Magic Heat Reclaimer?
1 answer-
ProductExpert31· 13 years ago
If you are going from a 6 inch pipe to an 8 inch adapter to the heat reclaimer then back to the 6 inch pipe that configuration will work with this unit, although the Magic Heat Reclaimer is designed for single wall pipe.
Helpful?
-
-
· 13 years ago
Can the Magic Heat Reclaimer be used on a waste oil heater?
1 answer-
ProductExpert41· 13 years ago
The Magic Heat Reclaimer can not be used on a waste oil heater. They are only for wood, oil, coal, or gas heaters.
Helpful?
-
-
· 14 years ago
what size do I need for an 8.5" diameter pipe
I measured the flue pipe diameter and it is about 8.5" in diameter, what size of Magic Heat Reclaimer will I need?
What would be the best way (ex. tool) to cut the flue pipe?
1 answer-
ProductExpert41· 14 years ago
The best way to cut flue pipe is with a compound miter saw. At Northern we only sell Magic Heat Reclaimers that fit 6" or 8" diameter pipes.
Helpful?
-
Warranty
Manufacturer's Warranty
12 months parts / 12 months labor
Extend Your Warranty Coverage with a Northern Protection Plan (NPP)
Replacement Plan — 1 Year
A Northern Protection Plan is available after adding the product to your shopping cart.
Compare with Most Popular in Heat Reclaimers
See All Heat Reclaimers
See All Heat Reclaimers
Currently Viewing This Product
Shipping: Sold Out
Item # 101753
$344.99Shipping:
Factory shippedStore Pickup:
Not available - online only
Item # 101752
$359.99Shipping:
Factory shippedStore Pickup:
Not available - online only
Specifications
1
1
1
Wood, Oil or Coal Stoves
Wood Burning Appliances
Wood Burning Appliances
18.25 in
-
-
225 cfm
225 cfm
225 cfm
115
110
110
10.625 W x 14.25 D x 18.25 H in
14.25 x 16.31 x 18.25 in
14.25 x 16.31 x 18.25 in
-
lb
lb