The transfer switch is designed for use with single phase generators that utilize an Evolution or Nexus Controller. The switch is designed for standby generators only using propane or natural gas.
Generac Service Entrance Rated Automatic Transfer Switch, 200 Amps, 120/240 Volts, Single Phase, Model# RXSW200A3

This is a carousel with one large zoomable image and a track of thumbnails on the left. Select any of the thumbnail buttons to change the zoomable image on the right. If a thumbnail is a video or 360 degree image thumbnail, or the last thumbnail in the list, the button will open the product media modal.

Click or Tap image to Zoom
This item is no longer available.
- Able to manage 4 individual HVAC loads with no additional hardware
- Designed for use with single-phase generators that utilize an Evolution or Nexus Controller
- Aluminum NEMA/UL Type 3R (indoor/outdoor) enclosure with electrostatically applied and baked power paint provides additional corrosion protection
- Gain even more flexibility when used in tandem with Smart Management Modules
- Smart A/C Module manages loads by shedding the connected loads in the event of a drop in generator frequency (overload)
See full description
Description
Key Specs
Reviews
Q & A
Warranty
Compare
Product Summary
What's Included
- (1) Automatic transfer switch, Model# RXSW200A3
Downloads
Features + Benefits
- Able to manage 4 individual HVAC loads with no additional hardware
- Designed for use with single-phase generators that utilize an Evolution or Nexus Controller
- Aluminum NEMA/UL Type 3R (indoor/outdoor) enclosure with electrostatically applied and baked power paint provides additional corrosion protection
- Gain even more flexibility when used in tandem with Smart Management Modules
- Smart A/C Module manages loads by shedding the connected loads in the event of a drop in generator frequency (overload)
Key Specs
| Attribute | Specification |
|---|---|
item# | 37850 |
Brand | Generac |
Manufacturer's Warranty | 5 year limited warranty |
Ship Weight | 30.0 LB |
| Attribute | Specification |
|---|---|
Amps | 200 |
Volts | 120/240 |
Phase | Single-phase |
UL Listed | Yes |
Reviews
Questions & Answers
Questions
-
· 12 years ago
Will this transfer switch work with any gasoline genaric generator? If so, what sizes?
-
ProductExpert5· 3 years ago
Helpful?
-
ProductExpert19· 12 years ago
None of Generac’s portable generators are compatible with the RTSY200A3 transfer switch.
Helpful?
-
Generac· 12 years ago
As long as the generator is sized appropriately for your particular application, the RTSY200A3 transfer switch is compatible with all current permanently installed 1-phase, 120/240v Generac brand generators featuring our Evolution or Nexus controllers. Furthermore, none of Generac’s portable generators are compatible with the RTSY200A3 transfer switch. We recommend working with a local certified dealer to ensure that you are utilizing the proper transfer switch for your desired configuration.
Helpful?
-
-
· 2 years ago
May I use it to transfer power from utility service to solar panel or battery instead generator?
1 answer-
ProductExpert11· 2 years ago
The transfer switch is designed specifically for the Generac automatic stand by generators. It will not work with a solar panel or battery set up.
Helpful?
-
-
· 4 years ago
Can the switch be operated manually if desired? Another words, can I engage to excercise the generator the resume to normal operation
1 answer-
ProductExpert37· 3 years ago
This transfer switch can be operated manually.
Helpful?
-
-
· 4 years ago
Will this connect to wifi the 200amp transfer switch model rxsw200a3
1 answer-
ProductExpert7· 4 years ago
Yes, as long as the Generac Standby Generator it is being used with is wi-fi compatible.
Helpful?
-
-
· 9 years ago
Can I use two of these in parallel off of the same generator?
1 answer-
ProductExpert6· 9 years ago
You would need to check with your installer or a certified electrician for your local codes and ordinances to see if this could be done.
Helpful?
-
-
· 11 years ago
What is the maximum startup delay?
The documentation stated that the factory default start-up delay (after power outage is detected) is 10 seconds. Can a longer delay be programmed to prevent nuisance start-ups in areas with frequent short duration (i.e. 5 minutes) power losses.
1 answer-
ProductExpert5· 10 years ago
Start up delay is a 10 second factory set, adjustable between 2-1500 seconds by a qualified dealer.
Helpful?
-
-
· 11 years ago
Is this the same Transfer Switch that come with the 11K unit that NorthernTools as a package
1 answer-
ProductExpert7· 11 years ago
This Generac transfer switch that comes with this standby generator is the same as the single transfer switch.
Helpful?
-
-
· 11 years ago
which transfer switch should I use?
I have a 2008 17 kw guardian that I need a 200 amp switch for. My house is all electric with one central heat and air unit. I want to be able too power the whole house if needed, but my main concern is the heat pump, fridge, and freezer, just in case the power goes out while we are away. which transfer switch would be best, with the least amount of wiring?
1 answer-
ProductExpert23· 11 years ago
Due to the fact that various factors will determine which automatic standby generator and automatic transfer switch should be utilized in your home’s configuration, we would recommend working with a certified electrician to determine the appropriate product’s for your home’s configuration. While a 200-amp automatic transfer switch may be applicable for application, we recommend you verify this with a certified electrician.
Helpful?
-
-
· 12 years ago
where are the knockouts on the box? what sizes?
1 answer-
ProductExpert6· 12 years ago
The transfer switch has 3 knockouts on it. One in the back top center is a 1 1/2" and 2" knockout. One on the left side at the bottom, if facing the box, it has a 1 1/2" and 2" knockout. The 3rd knockout is in the center on the bottom and is a 3/4" and 1" knockout.
Helpful?
-
-
· 12 years ago
How many circuits does the RTSY200A3 Smart Automatic Transfer Switch have ?
1 answer-
ProductExpert19· 12 years ago
This does not feature any pre-wired circuits. The switch is designed to be installed prior to the home’s main panel to provide whole-house protection for your backup power needs.
Helpful?
-
Warranty
Manufacturer's Warranty
5 year limited warranty
Compare with Most Popular in Generator Transfer Switches
See All Generator Transfer Switches
See All Generac Generator Transfer Switches
Currently Viewing This Product
Shipping: Sold Out
- $988.21
Shipping:
Free shipping (lower 48 states) - Factory shippedStore Pickup:
Not available - online only
- $809.99
Shipping:
Free shipping (lower 48 states) - Factory shippedStore Pickup:
Not available - online only
- $763.42
Shipping:
Free shipping (lower 48 states) - Factory shippedStore Pickup:
Not available - online only
Specifications
200
100
200
100
120/240
120/240
120/240
120/240
Single-phase
Single-phase
Single-phase
Single-phase
Yes
Yes
Yes
Yes
-
1
1
20
-
-
NEMA 3R
-
-
-
No
No
-
-
Yes
No
-
-
Indoor and Outdoor
-