This generator head has a 7/8" shaft. A coupling like item 115029 can be used. It would also require the insert, item 115017, and the appropriate half coupling for the engine shaft.
Free Gift Card Details
$100 Order
Original price:$250 Order
Original price:$500 Order
Original price:$1000 Order
Original price:- The promo code 289806 must be entered on the Shopping Cart page.
- To qualify for this offer, your order subtotal must equal $100 or more. Excludes gift cards, free item offers, warranties, Advantage memberships, tax and shipping.
- Free gift cards will be issued in the form of e-gift cards only, not physical gift cards.
- E-gift cards will be sent to the email address used in your billing address when your order ships or is picked up.
- Free e-gift cards expire .
- Promo code not valid on prior purchases or on Honda and STIHL products and cannot be combined with other promotional offers.
- Valid online and in participating retail stores.
- Limited-time offer. Subject to change without notice.
NorthStar Belt-Driven Generator Head, 2,900 Surge Watts, 2,600 Rated Watts, 5 HP Required

This is a carousel with one large zoomable image and a track of thumbnails on the left. Select any of the thumbnail buttons to change the zoomable image on the right. If a thumbnail is a video or 360 degree image thumbnail, or the last thumbnail in the list, the button will open the product media modal.

Click or Tap image to Zoom
Shipping:
Free shipping (lower 48 states) - Available nowStore Pickup:
Not available - online only
- Two 15 Amp 120V receptacles
- Two 15 Amp 240V receptacle
- Uses NEMA 5-15R and NEMA 6-15R plugs
- 21.7 Amps at 120 Volts, 10.8 Amps at 240 Volts
- 100% Copper windings
See full description
Description
Key Specs
Reviews
Q & A
Accessories
Warranty
Compare
Product Summary
What's Included
- (1) Generator
Downloads
Features + Benefits

- Two 15 Amp 120V receptacles
- Two 15 Amp 240V receptacle
- Uses NEMA 5-15R and NEMA 6-15R plugs
- 21.7 Amps at 120 Volts, 10.8 Amps at 240 Volts
- 100% Copper windings
- Brushless design, less than 6% Total Harmonic Distortion
- Bi-directional
- Thermal overload protection
- Conveniently located control panel
- Push button circuit breakers
- Plugs sold separately
- Note: Generator head does not include top mounting points as shown in photo.
Key Specs
| Attribute | Specification |
|---|---|
item# | 165915 |
Brand | NorthStar |
Manufacturer's Warranty | 12 months parts/12months labor |
Ship Weight | 37.2 LB |
Required Horsepower | 5 |
Shaft Diameter | 7/8 in |
| Attribute | Specification |
|---|---|
Rated Watts | 2,600 |
Surge Watts | 2,900 |
Continuous Run Time | Yes |
Receptacles (qty.) | 4 |
Product Weight | lb |
Dimensions L x W x H (in.) | 13.75 x 7.25 x 7.75 in |
Reviews
Questions & Answers
Questions
-
· 3 years ago
any direct couplers for this motor?
1 answer-
NorthstarExpert12· 3 years ago
Helpful?
-
-
· 3 years ago
Is it a wound rotor induction generator?
1 answer-
NorthstarExpert29· 3 years ago
This is a 100% copper wound induction generator head that uses a capacitor to produce reactive excitation current.
Helpful?
-
-
· 4 years ago
what is the shaft size also what are the distance between the mounting holes
1 answer-
NorthstarExpert12· 4 years ago
This generator head has a 7/8" diameter shaft. This has a square bolt pattern that is 5-1/4" from corner to corner.
Helpful?
-
-
· 5 years ago
Can I put this under the hood of my truck? And also the size of the pulley would determine the rpm at an idle, right?
1 answer-
NorthstarExpert29· 5 years ago
This generator head cannot be installed in the engine compartment of a vehicle. It requires a consistent RPM between 3,540 and 3,720 (3,600 recommended) RPM's to operate properly and would also have a higher risk of overheating. The size of the generator pulley would be determined by the engine pulley size and engine RPM's (Engine Pulley = Generator RPM (3,600) x Generator Pulley / Engine RPM.
Helpful?
-
-
· 6 years ago
Shaft internal thread size
Does anyone know the bolt\machine screw which will fit into the shaft of this unit?
1 answer-
NorthstarExpert30· 6 years ago
The shaft on this NorthStar Belt-Driven generator head is not tapped and is not designed to have a bolt installed in the end. This NorthStar Belt-Driven Generator Head is recommended to be connected using pulleys and a v-belt(s). An alternative method is to direct couple the generator to the engine with the use of LoveJoy couplings. This method requires great care to align the shafts of the generator and engine to within the specified tolerances of the chosen coupler.
Helpful?
-
-
· 9 years ago
Max Ambient Temp?
What is the maximum ambient temperature that this unit can be run in?
1 answer-
NorthstarExpert11· 9 years ago
This generator doesn't have a maximum ambient temperature restriction. Position it so there is adequate clearance around the generator head to allow for cooling airflow so that heat doesn't build up. The closest object should be at least 7 feet away from the vents.
Helpful?
-
-
· 10 years ago
How can I draw 22 amps from one 120V receptacle to power devices that draw that much current?
Is it a simple matter of modifying the wiring harness to connect both hot lines together and replacing the receptacle with a NEMA 5-20R?
1 answer-
NorthstarExpert12· 10 years ago
The NorthStar Belt-Driven Generator Head is only capable of producing 21.7 amps of 120 volt power or 10.8 amps of 240 volt power. Any modifications would void the warranty and would not be recommended.
Helpful?
-
-
· 10 years ago
Can this head be mounted directly to the shaft of a briggs and stratton engine? A.K.A. direct drive
1 answer-
NorthStarExperts· 10 years ago
This NorthStar Belt-Driven Generator Head is recommended to be connected using pulleys and a v-belt(s). An alternative method is to direct couple the generator to the engine with the use of LoveJoy couplings. This method requires great care to align the shafts of the generator and engine to within the specified tolerances of the chosen coupler.
Helpful?
-
-
· 11 years ago
Hertz?
I was hoping to send this to Ukraine, where the operating hertz are 50 not 60 like in the US. I know certain generator heads can be switched between 50/60 hertz by lowering the rpm. Is this the case with this generator head or is it rated only at 60 hertz? Thanks
1 answer-
NorthstarExpert13· 11 years ago
This generator head is only designed to run at a frequency of 58.0-63.0 hertz at 3480 - 3780 RPM.
Helpful?
-
-
· 15 years ago
can this run on a small wind turbine 24/7
1 answer-
NorthstarExpert29· 15 years ago
No, the NorthStar Belt-Driven Generator Head requires a minimum of a 5 horsepower engine running at 3600 RPM in order for this generator head to produce electricity.
Helpful?
-
Accessories We Recommend
This is a carousel with auto-rotating slides. Activate any of the buttons to disable rotation. Use Next and Previous buttons to navigate, or jump to a slide with the slide dots.
Warranty
Manufacturer's Warranty
12 months parts/12months labor
Extend Your Warranty Coverage with a Northern Protection Plan (NPP)
Repair Plan — 1 Year
A Northern Protection Plan is available after adding the product to your shopping cart.
Compare with Most Popular in Generator Heads
See All Generator Heads
See All NorthStar Generator Heads
Currently Viewing This Product
Item # 165915
$559.99Shipping:
Free shipping (lower 48 states) - Available nowStore Pickup:
Not available - online only
Item # 165913
$749.99Shipping:
Free shipping (lower 48 states) - Available nowStore Pickup:
Out of stock at Fredericksburg VA
Item # 165928
$1299.99Shipping:
Free shipping (lower 48 states) - Available nowStore Pickup:
Out of stock at Fredericksburg VA
Specifications
5
11
18
7/8 in
7/8 in
11/10 in
2,600
5,000
9,600
2,900
5,500
10,000
Yes
Yes
Yes
4
3
6
lb
lb
lb
13.75 x 7.25 x 7.75 in
16.25 x 7.5 x 7.75 in
19.5 x 14.25 x 9.0 in