The Norseman XB Explosion-Proof Natural Convection Heater is designed for heating applications where explosive substances may be present, such as control cabinets and small enclosures, storage rooms for paints and cleaners, grain elevators, flour mills, spray booths, gas plants, pump houses, oil platforms, cleaning and dyeing plants, and marine/offshore areas. From panel heaters to unit heaters, the Norseman™ line provides innovative forced air or natural convection solutions to your hazardous area heating requirements. This safe and reliable heater offers a state-of-the-art design, featuring unique copper-free aluminum extruded converter and patented x-Max® terminal housing. Norseman is the most technologically advanced line of explosion-proof electric air heaters and heating accessories, including both forced air heaters and natural convection heaters, as well as unit heaters, panel heaters, and thermostats. Norseman offers innovative, low-maintenance solutions for a wide range of applications in a variety of industrial and commercial environments. Custom-engineered heaters or heating systems are available for specialized applications. Flexibility in application and design. Product Applications Class I (Gas)
  • Oil platforms and refineries
  • Gas plants
  • Control cabinets and small enclosures
  • Water sewage treatment plants
  • Storage rooms for paints cleaners
  • Compressor stations Class II (Dusts)
  • Flour mills
  • Grain elevators
  • Cement plants
  • Pulp and paper mills Class III (Fibers)
  • Textile plants Features + Benefits XB Explosion-Proof Natural Convection Heaters Durable construction Anodized, copper copper-free housings and heat sinks Low-watt-density elements Simplified Wiring: “Track and Trolley” wiring system Explosion-Proof x-Max® Terminal Housing: Five standard sizes Used as a control station, junction box, disconnect, thermostat Designed for heating spaces where explosive substances may be present such as storage rooms for paints and cleaners, grain elevators, gas plants, and more. Offers a state-of-the-art design, featuring Thermon Heating Systems’ unique copper-free aluminum extruded convector and patented x-Max® terminal housing. Models are offered in 47.5 to 5130W and from 120 to 600V. cCSAus approved for Class I, Division 1 2, Groups A, B, C D; Class II, Division 1 2, Groups E, F, G; Class III, Division 1 2 at a temperature code of T2D, T3B, T4A or T6. CE/ATEX for II 2 G, Ex d IIC T3 or T4 Gb.
  • What's Included

      (1) Norseman™ Explosion-Proof Convection Heater c/w T'stat, 2,000W, 208V, 3Ø, Temp Code T2D (2x) 19 In Heat Sink Length

    Features + Benefits

    • XB Explosion-Proof Natural Convection Space Heaters
    • Designed for heating spaces where explosive substances may be present such as storage rooms for paints and cleaners, grain elevators, gas plants and more.
    • Offers a state of the art design, featuring Thermon Heating Systems’ unique copper-free aluminum extruded convecter and patented x-Max® terminal housing.
    • Models offered in 47.5 to 5130W and from 120 to 600V.
    • cCSAus approved for Class I, Division 1 & 2, Groups A, B, C & D; Class II, Division 1 & 2, Groups E, F, G; Class III, Division 1 & 2 at a temperature code of T2D, T3B, T4A or T6.
    • CE/ATEX for II 2 G, Ex d IIC T3 or T4 Gb.
    • Custom engineered heaters or heating systems are available for specialized applications.
    • Depending on the particular model ordered, the heater is suitable for the following areas: ? CSA C/US certified for Class I, Div. 1 and 2, Groups A, B, C, and D; Class II, Div. 1 and 2, Groups E, F, and G; Class III, Div. 1 and 2; Temperature Code T2D, T3B, T4A or T6. CSA type 4, Class I, Zone 1 and 2, Groups IIA, IIB and IIC.
    • Heaters marked with temperature code T2B are not suitable for Class II and Class III applications.
    • Operating ambient temperature: Standard XB Models: -50°C to 40°C High Ambient XB Models: -50°C to 70°C
    • General Requirements: Norseman™ XB heaters are approved for wall or floor mounting with the terminal housing at the bottom. Ensure that is the wall sufficiently strong to support the heater which, depending on the model, could weigh up to 100 lbs (45 kg). Otherwise use the brackets supplied to stand the heater on the floor.
    • Do not recess the Norseman™ XB heater into the wall. Use of the brackets supplied will ensure that the minimum spacing from the wall of 3.75" (95 mm) is maintained.
    • Do not recess the Norseman™ XB heater into the wall. Use of the brackets supplied will ensure that the minimum spacing from the wall of 3.75" (95 mm)
    • The Norseman™ XB heater relies on natural convection and “black heat” radiation to transfer heat to the surroundings. Try to maintain a 12" (300 mm) clearance and NEVER LESS THAN 6" (150 mm) clearance in front of and at the sides of the heater.
    • Use guard rails in front of the heater if there is a possibility that moving equipment could come in contact with the heater

    Key Specs

    AttributeSpecification

    item#

    7397119

    Brand

    Norseman

    Manufacturer's Warranty

    1 year limited warranty

    Ship Weight

    56.0 LB

    Heat Type

    Convection

    Heat Output

    0 Btu/hour

    Phase

    Three-phase

    Indoor Outdoor Use

    Indoor

    Volts

    208
    AttributeSpecification

    Watts

    2,000

    Hardwired

    Yes

    Thermostat Included

    Yes

    Mounting Hardware Included

    Yes

    Housing Material

    Aluminum

    Hazardous Location Rating

    EX II 2G Ex db IIC T3 or T4 Gb -60°C ? Ta ? +40°C