Free Gift Card Details
- The promotion will be automatically applied on the Shopping Cart page.
- To qualify for this offer, your order subtotal must equal $100 or more. Excludes gift cards, free item offers, warranties, Advantage memberships, tax and shipping.
- Free gift cards will be issued in the form of e-gift cards only, not physical gift cards.
- E-gift cards will be sent to the email address used in your billing address when your order ships or is picked up.
- Free e-gift cards expire 03/01/27.
- Promo code not valid on prior purchases or on Honda and STIHL products and cannot be combined with other promotional offers.
- Valid online and in participating retail stores.
- Limited-time offer. Subject to change without notice.
Cata-Dyne™ Infrared Gas Catalytic Heater for Hazardous Locations, 6"x 24", 6,000 BTU/Hr, 115V, BX Catalyst Pad, 3.5” W.C. Natural Gas, Thmcpl, FM Certified

This is a carousel with one large zoomable image and a track of thumbnails on the left. Select any of the thumbnail buttons to change the zoomable image on the right. If a thumbnail is a video or 360 degree image thumbnail, or the last thumbnail in the list, the button will open the product media modal.

Click or Tap image to Zoom
Shipping:
Factory shippedStore Pickup:
Not available - online only
- Applications: The large surface area of the Cata-Dyne™ heater allows for efficient transfer of infrared heat that can be used in a variety of applications including: - Facility space heating - Process heating - Freeze protection - Comfort heating for personnel - Ovens
- Certifications: G Series catalytic pad is certified by the Canadian Standards Association (CSA) and Factory Mutual (FM) and (European standards) for non-hazardous area applications.
- Internal heater components such as our proprietary catalyst pad and preheat Caloritech™ tubular element are manufactured in-house
- Multiple Btu input ratings and a variety of standard heater sizes are available
- Offered in a variety of preheating voltages
See full description
Description
Key Specs
Reviews
Q & A
Warranty
Compare
Product Summary
What's Included
- (1) Cata-Dyne™ Infrared Gas Catalytic Heater for Hazardous Locations, 6"x 24", 6,000 BTU/Hr, 115V, BX Catalyst Pad, 3.5” W.C. Natural Gas, Thmcpl, FM Certified
Features + Benefits
- Applications: The large surface area of the Cata-Dyne™ heater allows for efficient transfer of infrared heat that can be used in a variety of applications including: - Facility space heating - Process heating - Freeze protection - Comfort heating for personnel - Ovens
- Certifications: G Series catalytic pad is certified by the Canadian Standards Association (CSA) and Factory Mutual (FM) and (European standards) for non-hazardous area applications.
- Internal heater components such as our proprietary catalyst pad and preheat Caloritech™ tubular element are manufactured in-house
- Multiple Btu input ratings and a variety of standard heater sizes are available
- Offered in a variety of preheating voltages
- Natural gas (NG) or propane (LPG) configurations
- Choice of manual control or electronic control options
- Multiple heater mounting bracket configurations are available
- The heater contains no moving parts and is designed to operate indefinitely when supplied with air and clean fuel
- Space Heating: A separate heat load calculation should be done for each building in which a Cata?Dyne™ heater will be installed for space heating purposes.
- Space Heating: The heat load calculation determines the building heat losses through the structure and allows for air infiltration. For sample Heat Load Calculation, visit: www.thermon.com.
- Cata?Dyne™ heaters produce low intensity infrared heat that is absorbed by objects within the range of the heat source. The closer the object is to the source of heat the more heat the object will absorb. Cata?Dyne™ heaters should be placed close to the floor level within the building to heat objects close to the floor.
- Ideally, Cata?Dyne™ heaters should be mounted 1 ft to 3 ft (0.3 m to 1 m) from the floor and equally spaced around the building perimeter for space heating applications.
- If low mounting is not practical, then overhead mounting may be utilized. Overhead mounted heaters should be sloped face down to a maximum 45° angle to direct the infrared energy towards the floor. Overhead mounting should be restricted to heaters of 30,000 Btu/hr (8.8 kW) capacity and larger.
- If the building requires only one heater, place the Cata?Dyne™ heater as close as possible to the center of the longest wall.
Key Specs
| Attribute | Specification |
|---|---|
item# | 7387527 |
Brand | Cata-Dyne |
Manufacturer's Warranty | 1 year limited warranty |
Ship Weight | 16.0 LB |
Heat Type | Infrared |
Heat Output | 6,000 Btu/hour |
Phase | Single-phase |
Indoor Outdoor Use | Indoor |
Volts | 115 |
| Attribute | Specification |
|---|---|
Watts | 1,758 |
Amps | 2.1 |
Hardwired | Yes |
Thermostat Included | No |
Mounting Hardware Included | No |
Housing Material | Stainless Steel |
Hazardous Location Rating | Factory Mutual (FM) for use in Class I, Division 1, Group D hazardous locations. Temperature code T2C at an ambient temperature of 40°C (104°F). This style heater is only sold in the USA. |
Product Weight | 16.0000 lb |
Dimensions L x W x H (in.) | 28.0 x 17.0 x 12.0 in |
Reviews
Questions & Answers
Questions
Warranty
Manufacturer's Warranty
1 year limited warranty
Compare with Most Popular in Hazardous Location + Explosion-Proof Heaters
See All Hazardous Location + Explosion-Proof Heaters
See All Cata-Dyne Hazardous Location + Explosion-Proof Heaters
Currently Viewing This Product
$625.99Shipping:
Factory shippedStore Pickup:
Not available - online only
- $2605.00
Shipping:
Factory shippedStore Pickup:
Not available - online only
- $1199.99
Shipping:
Factory shippedStore Pickup:
Not available - online only
- $1729.99
Shipping:
Factory shippedStore Pickup:
Not available - online only
Specifications
Infrared
Convection
Convection
Convection
6,000 Btu/hour
12,283 Btu/hour
2,388 Btu/hour
3,412 Btu/hour
Single-phase
-
-
-
Indoor
Indoor
Indoor
Indoor
115
240
120
480
1,758
3,600
700
1,000
2.1
15
5.9
2.1
Yes
Yes
Yes
Yes
No
-
-
-
No
-
-
-
Stainless Steel
-
-
-
Factory Mutual (FM) for use in Class I, Division 1, Group D hazardous locations. Temperature code T2C at an ambient temperature of 40°C (104°F). This style heater is only sold in the USA.
-
-
-
16.0000 lb
55.0000 lb
6.0000 lb
20.0000 lb
28.0 x 17.0 x 12.0 in
8.25 x 37.0 x 20.5 in
6.5 x 16.0 x 5.5 in
8.5 x 6.75 x 23.5 in
See All Hazardous Location + Explosion-Proof Heaters
See All Cata-Dyne Hazardous Location + Explosion-Proof Heaters
Recently Viewed Items
This is a carousel with auto-rotating slides. Activate any of the buttons to disable rotation. Use Next and Previous buttons to navigate, or jump to a slide with the slide dots.



